Fast commissioning / operating principle
18
BCL 504
i
Leuze electronic
3.4.1
Setting the device address on the display
The display of the BCL 504
i
possesses an important function for setting the PROFIBUS
address. The PROFIBUS address is set here, i.e. the respective station number of the
network device.
Notice!
The address setting can only be performed via the display if parameter enabling is active.
Information on this topic can be found in chapter "Parameter enabling" on page 93.
The set address must be >
≥
0 and < 126. Each network device is thereby automatically
informed that it is a slave on the PROFIBUS with its specific address and that it is initialised
and queried by the PLC.
The PROFIBUS permits an address range from 0 to 126. Address 126 must not be used for
data communication. It may only be used temporarily for commissioning. The default
address is 126.
The address must be assigned individually for each barcode reader of type BCL 504
i
; this
can be performed by making entries on the display or with the webConfig tool.
Notice!
The BCL 504
i
does not permit address assignment via the PROFIBUS!
To set the address via the display, proceed as follows:
In the main menu, use the
buttons to select the Parameter menu and use the enter
button
to activate the Parameter menu. The following screen appears:
Parameter 1
Parameter handling
Decoder table
Digital SWIO
PROFIBUS
In the Parameter menu, use the
buttons to select the
PROFIBUS
menu item.
Press the enter button to enter the
PROFIBUS
menu.
PROFIBUS
o PROFIBUS address
Press the enter button again to enter the menu for setting
the PROFIBUS address.
PROFIBUS address
12|
<-|0123456789 save
Standard ----- Unit
126 | |
Use the
and
buttons to set the desired PROFI-
BUS address. An accidental, incorrect entry can be cor-
rected by selecting
<-|
and then pressing
.
Then use the
buttons to select
save
and save the
set PROFIBUS address by pressing
.