Commissioning and configuration
138
BCL 504
i
Leuze electronic
Parameter length
8 byte
Input data
None
Output data
None
All comparison criteria are AND linked; this means all active comparisons must be fulfilled
before the just-decoded barcode can be identified as already decoded and then deleted.
Comparison
parameter - oscil-
lating mirror posi-
tion
If this parameter is not
equal to 0, the barcode
position in the swivel range
of the oscillating mirror is
used to determine whether
identical barcodes have
already been decoded. A +/
- bandwidth in degrees
must then be specified,
within which the same bar-
code is permitted to be in
the oscillating mirror swivel
range.
4
…
5
UNSIGNED16
0 … 200
0
1/10
degree
Comparison
parameter - scan-
ning time info
If this parameter is not
equal to 0, the decoding
time (time at which the bar-
code was decoded) is used
to determine whether iden-
tical barcodes have already
been detected. Here, a dif-
ference time specified in
milliseconds ensures
that identical barcodes may
only occur within this time.
6
…
7
UNSIGNED16
0 … 65535
0
ms
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Table 10.32:
Parameters for module 50