Device description
Leuze electronic
BCL 504
i
29
TNT 35/7-24V
4.7
External parameter memory
The optionally available external parameter memory –
based on a USB memory stick (compatible with
version 1.1) – is housed in an external hood with inte-
grated connectors which cover the USB service inter-
face when installed (IP 65). By having available a
copy of the current parameter set of the BCL 504
i
, the
external parameter memory makes it easy and
reduces the time needed to replace the BCL 504
i
on
site. A manual configuration of the exchanged device
is thereby omitted.
During operation of the BCL 504
i
on the PROFIBUS, the parameters are stored in the PLC.
It is not necessary to use the external parameter memory in this case.
The delivery contents of the external parameter memory include the hood with integrated
connectors with unscrewable cover and the USB memory stick.
Figure 4.8:
External parameter memory
Notice!
To mount, the cover of the hood with integrated connectors must be unscrewed. The tube
is then screwed onto the USB connection on the BCL 504
i
after which the USB memory stick
is plugged into the connection and the hood with integrated connectors closed with the cover
in order to ensure protection class IP 65.