Commissioning and configuration
110
BCL 504
i
Leuze electronic
Code type 3
See code type 1
17.0
…
17.5
BitArea
See code type 1
0
-
Number-of-
digits mode 3
Specifies how the subsequent numbers of
digits are to be interpreted.
18.6
Bit
0: Enumeration
1: Range
0
-
Digits 3.1
Decodable number of digits; in the case of a
range, this number defines the lower limit.
18.0
…
18.5
UNSIGNED8
0 … 63
0
-
Digits 3.2
Decodable number of digits; in the case of a
range, this number defines the upper limit.
19
UNSIGNED8
0 … 63
0
-
Digits 3.3
Decodable number of digits in the
enumera-
tion
mode.
20
UNSIGNED8
0 … 63
0
-
Digits 3.4
Decodable number of digits in the
enumera-
tion
mode.
21
UNSIGNED8
0 … 63
0
Digits 3.5
Decodable number of digits in the
enumera-
tion
mode.
22
UNSIGNED8
0 … 63
0
-
Reading relia-
bility 3
Min. reading reliability to be achieved in order
to output a read code.
23
UNSIGNED8
1 … 100
4
-
Check digit
procedure 3
Used check digit procedure
24.0
…
24.6
BitArea
0: Standard check
digit evaluation
1: No check digit veri-
fication
2: MOD10 Weight 3
3: MOD10 Weight 2
4: MOD10 Weight 4_9
5: MOD11 Cont
6: MOD43
7: MOD16
0
-
Check digit
output 3
Turns the check digit output on or off.
24.7
Bit
Check digit output
0: Standard
1: Not standard
0
-
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Table 10.5:
"Common" Parameters