Commissioning and configuration
Leuze electronic
BCL 504
i
175
TNT 35/7-24V
10.14.4 Module 84 – Reference code comparison pattern 2
Description
This module can be used to define the 2nd comparison pattern
Parameters
Parameter length
31 byte
Input data
None
Output data
None
Notice!
The defined comparison pattern affects both reference code comparators (Module 81 –
Reference code comparator 1 and Module 82 – Reference code comparator 2).
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Code type
comparison
pattern 2
Specifies the type of the reference
barcode.
0
UNSIGNED8
0: 0: No code
1: 2/5 Interleaved
2: Code39
3: Code32
6: UPC, UPCE
7: EAN8, EAN13
8: Code128
10: EAN Addendum
11: Codabar
12: Code93
13: RSS-14
14: RSS Limited
15: RSS Expanded
0
-
Comparison
pattern 2
Parameter string describing the con-
tent of the reference barcode. Note:
You can also use the two placeholder
characters that are stored in the
"Wildcard character" and "Don't care
character" parameters. If the string is
empty, no comparison takes place. If
the most recently stored character is
the wildcard character, the compari-
son is only carried out up to the char-
acter before this wildcard character.
In this way it is possible to switch off a
comparison according to barcode
length.
1
STRING
30 characters
null termi-
nated
1 … 30 bytes of
ASCII characters
\00
-
Table 10.58:
Parameter module 84 – Reference code comparison pattern