Display and control panel
92
BCL 504
i
Leuze electronic
Start auto-setup
The auto-setup function provides an easy option for configuring the code type and number
of digits of
Decoder 1
.
ª
Use the
button to activate the auto-setup function and place an unknown barcode in
the reading beam of the BCL 504
i
.
The following display appears:
The following information is displayed:
xx
Code type of the detected code (sets the code type of Decoder 1)
’01’
2/5 Interleaved
’02’
Code 39
’06’
UPC (A, E)
’07’
EAN
’08’
Code 128, EAN 128
’10’
EAN/UPC
’11’
Codabar
yy
Number of digits of the detected code (sets the number of digits of Decoder 1)
zzzzzz
:
Contents of the decoded label. A
↑
appears if the label was not correctly read.
Start teach-in
The teach-in function can be used to conveniently read reference code 1.
ª
Use the
button to activate the teach-in function and place a barcode which contains
the content that you wish to store as the reference code in the reading beam of the
BCL 504
i
.
The following display appears:
The following information is displayed:
RC13
means that reference code number 1 is stored in RAM. This is always output.
xx
defined code type (see auto-setup)
z
defined code information (1 … 63 characters)
Actions
o Stop auto-setup
xx yy zzzzzz
Actions
o Stop teach-in
RC13xxzzzzzz