Commissioning and configuration
142
BCL 504
i
Leuze electronic
Output with
identifier
If this switch is not set, the output of the
identifiers is suppressed. In this case,
only the data values belonging to the
identifiers are displayed.
25.0
Bit
0: Output of
the identifi-
ers is sup-
pressed.
1: Identifiers
are output.
1
-
Output delim-
iter
This delimiter, if not equal to 0, is
inserted between the identifier and the
associated data value in the output.
26
UNSIGNED8
0 … 127
0
-
Fixed positions
Start position
of the 1st iden-
tifier
Specifies the position of the first char-
acter of the first identifier in the data
string of the barcode.
The first character in the barcode has
position 1. If the parameter is = 0, it is
deactivated.
27
UNSIGNED8
0 … 127
0
-
Start position
of the 1st data
value
Specifies the position of the first char-
acter of the first data value in the data
string of the barcode.
The first character in the barcode has
position 1. If the parameter is = 0, it is
deactivated.
28
UNSIGNED8
0 … 127
0
-
Start position
of the 2nd
identifier
Specifies the position of the first char-
acter of the second identifier in the data
string of the barcode.
The first character in the barcode has
position 1. If the parameter is = 0, it is
deactivated.
29
UNSIGNED8
0 … 127
0
-
Start position
of the 2nd data
value
Specifies the position of the first char-
acter of the second data value in the
data string of the barcode.
The first character in the barcode has
position 1. If the parameter is = 0, it is
deactivated.
30
UNSIGNED8
0 … 127
0
-
Start position
of the 3rd iden-
tifier
Specifies the position of the first char-
acter of the third identifier in the data
string of the barcode.
The first character in the barcode has
position 1. If the parameter is = 0, it is
deactivated.
31
UNSIGNED8
0 … 127
0
-
Start position
of the 3rd data
value
Specifies the position of the first char-
acter of the third data value in the data
string of the barcode.
The first character in the barcode has
position 1. If the parameter is = 0, it is
deactivated.
32
UNSIGNED8
0 … 127
0
-
Start position
of the 4th iden-
tifier
Specifies the position of the first char-
acter of the fourth identifier in the data
string of the barcode.
The first character in the barcode has
position 1. If the parameter is = 0, it is
deactivated.
33
UNSIGNED8
0 … 127
0
-
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Table 10.35:
Parameters for module 53