Commissioning and configuration
144
BCL 504
i
Leuze electronic
10.10.3 Module 54 – Segmentation according to identifier and separator
Description
This module activates the segmentation according to identifier and separator. The parame-
ters specify the identifiers to be searched for, the output mode, and the parameters for the
identifier/separator algorithm.
Parameters
Parameter length
29 byte
Input data
None
Output data
None
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Identifier list
Identifier 1
The identifier string is used for the iden-
tifier list and the filtering according to
the segmentation.
0
STRING
5 characters
null terminated
1 … 5 bytes of
ASCII characters
‘*‘
-
Identifier 2
See identifier 1.
5
STRING
5 characters
null terminated
1 … 5 bytes of
ASCII characters
\0
-
Identifier 3
See identifier 1.
10
STRING
5 characters
null terminated
1 … 5 bytes of
ASCII characters
\0
-
Identifier 4
See identifier 1.
15
STRING
5 characters
null terminated
1 … 5 bytes of
ASCII characters
\0
-
Identifier 5
See identifier 1.
20
STRING
5 characters
null terminated
1 … 5 bytes of
ASCII characters
\0
-
Identifier output
Output with
identifier
If this switch is not set, the output of the
identifiers is suppressed. In this case,
only the data values belonging to the
identifiers are displayed.
25.0
Bit
0: Output of
the identifi-
ers is sup-
pressed.
1: Identifiers
are output.
1
-
Output delim-
iter
This delimiter, if not equal to 0, is
inserted between the identifier and the
associated data value in the output.
26
UNSIGNED8
0 … 127
0
-
Segmentation acc. to identifier and separator
Identifier
length
Fixed length of all identifiers in the seg-
mentation process. After this length,
the text of the identifier ends and the
associated data value starts. The end
of the data value is determined by the
separator.
27
UNSIGNED8
0 … 255
0
-
Delimiter in the
identifier/sepa-
rator algorithm
The separator terminates the data
value that follows its identifier directly
after the identifier length. After the sep-
arator, the next identifier starts.
28
UNSIGNED8
0 … 127
0
-
Table 10.36:
Parameters for module 54