Step 2 —
Set Up Hardware (RS-232)
Hardware for RS-232
Installation Steps for RS-232
1. Power-off the host.
2. Attach the RS-232 cable to the
Mobile Hawk.
3. Connect the RS-232 cable to
the power supply cable.
4. Plug in the power supply and
power-on the host.
5. Open a terminal program
(HyperTerminal, for example)
and set
57.6K
baud rate,
8
data bits,
none
parity, and
2
stop bits.
6. Read the
Reset to RS-232 Factory Defaults
symbol
below.
7. Read the
Save Settings
symbol below.
1
Mobile Hawk Handheld DPM Imager FIS-6170-0001G
3
RS-232 Interface Kit (USA)
98-000074-04
RS-232 Interface Kit (Europe)
98-000074-05
RS-232 Interface Kit (UK)
98-000074-06
RS-232 Hardware
Reset to RS-232
Factory Defaults
Save
Settings
Test Symbol
Quick Start Guide
Mobile Hawk
Handheld DPM Imager
P/N 83-110022 Rev A
Step 2 — Set Up Hardware (USB)
Note:
The USB interface draws its power from the host.
Hardware for USB
Installation Steps for USB
1. Connect the USB cable (
2
) to
the Mobile Hawk (
1
).
2. Connect the USB cable (
2
) to
the host. You do not need to
power off your host computer.
3. Open any program in your
host computer that can receive
keyboard text.
4. Read the
Reset to USB Factory
Defaults
symbol below.
Note:
If you want symbol data
to be entered as keyboard text, read the
USB Keyboard
Mode
symbol below.
5. Read the
Save Settings
symbol below.
1
Mobile Hawk Handheld DPM Imager FIS-6170-0001G
2
USB Cable
Included
USB Hardware
Reset to USB
Factory
Defaults
Save
Settings
Test Symbol
USB Keyboard
Mode
Step 1 — Check Required Hardware
Mobile Hawk USB Hardware
1. One Mobile Hawk Handheld DPM Imager
2. One 12 ft. USB cable (pre-installed)
Mobile Hawk RS-232 Hardware
The RS-232 cable is affixed to the handle with two screws, a spacer,
and a cable clip, which can be removed.
1. One Mobile Hawk Handheld DPM Imager
2. Cable clip attachment
3. Spacer
4. Two threaded screws
5. RS-232 Interface Kit (Optional Accessory)
• 8 ft. coiled RS-232 cable
• Power supply (U.S. Euro, or UK)
Refer to the
Mobile Hawk Handheld DPM Imager User’s Manual
for
information about changing or adding cables.
Step 3 — Install ESP
ESP Software
can be found on the Microscan Tools CD that is packaged
with the Mobile Hawk.
1. Follow the prompts to install ESP from the CD.
2. Click on the ESP icon to run the program.
Note:
ESP can also be installed from the
Download Center
at
Minimum System Requirements
• 166 MHz Pentium processor (Pentium II processor recommended)
• Windows Vista, XP, or 2000 operating system
• Internet Explorer 5.0 or higher
• 64 MB minimum RAM (128+ MB RAM recommended)
• 80 MB hard drive space
• 800 x 600 minimum 256 color display (1024 x 768 32-bit color
recommended)
Important:
The imager must be in USB or RS-232 Mode to connect
to
ESP
. Read the symbol below that corresponds with your communication
interface.
USB
Mode
RS-232
Mode
Step 4 — Select Model
When you start
ESP
, the following menu will appear:
1. Click the Mobile Hawk button and then click
OK
. If you do
not want to make this selection every time you start
ESP
,
uncheck “Show this dialog at startup”.
2. Select the default imager name (
Mobile Hawk-1
), or type a
name of your choice in the
Description
text field and click
OK
.
3. Click
Yes
when this dialog appears: