CLEAR

Clears Preamble
and Postamble.
Resets scanned
parameter back to
default settings.

Preamble

Scan up to 15 characters
from the Full ASCII
Menu. Scan

SET

when

finished

Beep Options

* 0)  Ack.

1) Ack Only

RESET

WARNING!

Scanning RESET after scanning START

SETUP resets the reader back to DEFAULT settings,
eliminating any setup changes for all parameters.

MSI/Plessey

* 0) Disable

1) Enable 1 Mod 10
2) Enable 2 Mod 10
3) Enable Mod 11/Mod 10

* 4) Transmit no check digit

5) Transmit 1 check digit

6) Transmit 2 check digits

7)Enable Plessey bar code

Code 128

0) Disable Code 128

* 1) Enable Code 128

2) Disable UCC/EAN 128

* 3) Enable UCC/EAN 128

Codabar

0) Enable Codabar

* 1) Disable Codabar

2) Enable CLSI Codabar

* 3) Disable CLSI Codabar
* 4) Suppress Start/Stop

5) Enable Start Stop

UPC and EAN

* 0) Enable UPC/EAN
1) Disable UPC/EAN
2) Enable Supplements

*

3) Disable Supplements

* 4) Transmit UPC-A NSC

5) Don’t Transmit UPC-A NSC

* 6) Transmit UPC-A Check Digit

7) Don’t Transmit UPC-A Check Digit
8) Transmit UPC-E NSC and EAN-8 Flag Ch

* 9) Don’t Transmit UPC-E NSC or EAN-8 Flag Ch

A) Transmit UPC-E/EAN-8 Check Digit

* B) Don’t Transmit UPC-E/EAN-8 Check Digit
* C) UPC-E Compressed Transmission

D) UPC-E Expanded Transmission

* E) EAN-8 observes 9 & A above

F) EAN is forced to transmit 8 digits always

Code 93

0) Enable

* 1) Disable

2) Enable Full ASCII

* 3) Disable Full ASCII

2 of 5 Code

0) Enable I 2of5

* 1) Disable I 2of5

2) Enable Check Digit

* 3) Disable Chk Digit

4)Transmit Check Digit

* 5) Don’t Transmit Ck

6) Enable 2 of 5

* 7) Disable 2 of 5

Code 3 of 9

* 0) Enable Code 39

1) Disable Code 39

* 2) Enable Full ASCII

3) Disable Full ASCII

* 4) Enable Accumulate Mode

5) Disable Accumulate Mode
6) Transmit Start/Stop

* 7) Don’t Transmit Start/Stop

8) Enable Mod 43 Check Character

* 9) Disable Mod 43 Check Character

A) Transmit Mod 43 Check Character

* B) Don’t Transmit Mod 43 Check Character

C) Caps Lock ON

* D) Caps Lock OFF

Barpad Table

LZ360-RF & LZ404-RF Laser Setup Menu

Start Setup

End Setup

1) scan “

Start Setup

” to put RF Laser into setup mode .

2) scan

parameter

to change, (i.e. Code 3 of 9, Postamble ).

3) scan corresponding bar codes from

Barpad Table

(0-9,A-F) to change settings.

4) scan “

End Setup

” after all changes have been made.

Instant Setup options in

RED

section do not require scanning

Start Setup

*/A/*

*/B/*

*0*

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

*/+/*

*/-/*

*/C/*

*/D/*

*/1/*

*/5/*

*/S/*

*/R/*

*1*
*2*
*3*
*4*
*5*
*6*
*7*

*/2/*

*8*
*9*

*A*
*B*
*C*

*D*
*E*

*F*

*///*

*/W/*

*/./*

*/L/*

* default setting 04/12

*/$/*

2 of 5 Length

Scan 2 digit length
(default is 06)

Postamble

Scan up to 15 characters
from the Full ASCII
Menu.Scan

SET

when

finished.

GS1-14

* 0) Disable

1) Standard 14 digits
2) 14 + Identifiers
3) 14 + UCC-128 Emul.

*/%/*

SET

Aiming Dot Duration (LZ404RF ONLY)

Scan 1 digit from the
Barpad Menu, from 0
to 9 seconds

*/K/*

Laser Status

(Instant Setting)

*/$A/*

Transmit Setup

(Instant Setting)

*/$C/*

Link Test Code

(Instant Setting)

Test RF Transmission
without
tramsmitting data.

*--*

Characters

Redefines
output for
characters

*.1.*

*/$B/*

*/$F/*

Pair Laser to Base

(Instant Setting)

Range Test

(Instant Setting)

Terminator Character

* 0) CR (Enter)

1) Tab
2) None

*/H/*