Commissioning and configuration
104
BCL 504
i
Leuze electronic
10.3
Address setting
10.3.1
Setting the device address on the display
The display of the BCL 504
i
possesses an important function for setting the PROFIBUS
address. The PROFIBUS address, i.e. the respective station number of the network device,
is set there.
Notice!
The address setting can only be performed via the display if parameter enabling is active.
Information on this topic can be found in chapter "Parameter enabling" on page 93.
The set address must be
≥
0 and < 126. Each network device is thereby automatically
informed that it is a slave on the PROFIBUS with its specific address and that it is initialised
and queried by the PLC.
The PROFIBUS permits an address range from 0 to 126. Address 126 must not be used for
data communication. It may only be used temporarily for commissioning. The default
address is 126.
The address must be assigned individually for each barcode reader of type BCL 504
i
; this
can be performed by making entries on the display or with the webConfig tool.
Notice!
The BCL 504
i
does not permit address assignment via the PROFIBUS!