Commissioning and configuration
116
BCL 504
i
Leuze electronic
Parameter length
8 bytes
Input data
None
Output data
None
Reading reliabil-
ity
Min. reading reliability to
be achieved in order to
output a read code.
6
UNSIGNED8
1 … 100
4
-
Check digit pro-
cedure
Used check digit proce-
dure
7.0 … 7.6
BitArea
0: Standard check
digit evaluation
1: No check digit
verification
2: MOD10 Weight 3
3: MOD10 Weight 2
4: MOD10
Weight 4_9
5: MOD11 Cont
6: MOD43
7: MOD16
0
-
Check digit out-
put
Turns the check digit out-
put on or off. >Standard
means that the check
digit is transmitted
according to the applica-
ble standard for the
selected code type
If
no check digit trans-
mission is intended
for
the selected code type,
then "
Standard
" means
that the check digit is
not
transmitted and "
Not
Standard
" means that
the check digit is trans-
mitted anyway.
7.7
Bit
Check digit output
0: Standard
1: Not standard
0
-
1)
Cf. in section 10.4.4 Permanently defined parameters / device parameters the notice on
number of digits.
Parameter
Description
Rel. addr.
Data type
Value range
Default
Unit
Table 10.7:
Parameters for modules 1-4