Commissioning and configuration
108
BCL 504
i
Leuze electronic
10.4.4
Permanently defined parameters / device parameters
On the PROFIBUS, parameters may be stored in modules or may be defined permanently
in a PROFIBUS participant.
The permanently defined parameters are called "common" parameters or device-specific
parameters, depending on the configuration tool.
These parameters must always be present. They are defined outside of the modules and
are permanently anchored in the telegram header.
Hilscher Master Controller
In SyCon, the permanently defined parameters are set via
slave configuration -> param-
eter data -> common
. The module parameters are set via
slave configuration -> param-
eter data -> module
.
Simatic S7 Controller
In Simatic Manager, the permanently defined parameters are set via object properties of the
device. The module parameters are set via the module list of the selected device. By
selecting the project properties of a module, the respective parameters may be set if
required.
The following list contains the parameters that are permanently defined in the BCL 504
i
but
are configurable. These parameters always exist and are available independent of the
modules.
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Profile
number
Number of the activated profile. For
BCL 504
i
: constant with value 0
0
Byte
0 … 255
0
-
Code type 1
Released code type; no code means that all
subsequent code tables are also deactivated.
The valid number of digits also depends on
the code type.
1.0
…
1.5
BitArea
0: 0: No code
1: 2/5 Interleaved
2: Code39
2: Code32
6: UPC, UPCE
7: EAN8, EAN13
8: Code128
10: EAN Addendum
11: Codabar
12: Code93
13: RSS-14
14: RSS Limited
15: RSS Expanded
0 -
Number-of-
digits mode
Specifies how the subsequent numbers of
digits are to be interpreted.
2.6
Bit
0: Enumeration
1: Range
0
-
Digits 1
Decodable number of digits; in the case of a
range, this number defines the lower limit.
1)
2.0
…
2.5
UNSIGNED8
0 … 63
1
-
Digits 2
Decodable number of digits; in the case of a
range, this number defines the upper limit.
3
UNSIGNED8
0 … 63
0
-
Digits 3
Decodable number of digits in the
enumera-
tion
mode.
4
UNSIGNED8
0 … 63
0
-
Digits 4
Decodable number of digits in the
enumera-
tion
mode.
5
UNSIGNED8
0 … 63
0
-
Digits 5
Decodable number of digits in the
enumera-
tion
mode.
6
UNSIGNED8
0 … 63
0
-
Table 10.5:
"Common" Parameters