Fast commissioning / operating principle
Leuze electronic
BCL 504
i
17
TNT 35/7-24V
3.3
Electrical connectionBCL 504
i
The
BCL 504
i
is equipped with four M12 plugs/sockets which are A- and B-coded.
Figure 3.1:
Connections of the BCL 504
i
The
voltage supply
(10 … 30VDC) is connected at the
PWR
M12 connector.
Available at both the
PWR
M12 connector as well as at the
SW IN/OUT
M12 socket are
four
freely programmable switching inputs/outputs
for custom adaptation to the respective
application. Detailed information on this topic can be found in chapter 7.2.1 and chapter
7.2.3.
The
PROFIBUS
is connected via
BUS IN
, or, in the case of a continuing network, via
BUS OUT
. If BUS OUT is not used, the PROFIBUS must be terminated at this point with an
M12 terminating resistor (see chapter 12.3 "Accessory terminating resistor"). In the case of
a stub cable, BUS OUT can remain open.
3.4
Starting the device
ª
Connect the supply v10 … 30VDC (typ. +24VDC); the BCL 504
i
starts up and
the barcode reading window appears on the display:
As a first step, you need to set the device address of the BCL 504
i
.
SW IN/OUT
VOUT 1
2
3
4
SWIO_1
SWIO_2
GND
FE
5
HOST / BUS IN
N.C. 3
2
1
4
FE
A (N)
B (P)
N.C.
5
SERVICE
2 1
3
4
GND D+ D- U
B
PWR
SWIO_4
SWIO_3
3
2
1
4
5
GND
VIN
FE
BUS OUT
VP 1
2
3
4
A (N)
B (P)
GND485
FE
5
USB socket
Type A
M12 socket
(A-coded)
M12 socket
(B-coded)
M12 plug
(B-coded)
M12 plug
(A-coded)
By default, parameter enabling is deactivated and you can-
not change any settings. If you wish to carry out the config-
uration via the display, you must activate parameter
enabling. Further information can be found in chapter
"Parameter enabling" on page 93.
31