Commissioning and configuration
Leuze electronic
BCL 504
i
151
TNT 35/7-24V
10.11.5 Module 64 – Oscillating mirror
Description
Module for supporting the oscillating mirror.
Parameters
Parameter length
6 byte
Input data
None
Output data
None
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Oscillation
mode
This parameter defines the
mode in which the oscillating
mirror operates.
0
UNSIGNED8
0: Single oscillation
1: Double oscilla-
tion
2: Continuous
oscillation
3: Continuous
oscillation, oscil-
lating mirror
moves to the
start position at
the end of the
reading gate.
2
-
Start position
Start position (opening angle)
relative to the zero position of
the swivel range.
1 … 2
SIGNED16
-200 … +200
200
1/10°
Stop position
Stop position (opening angle)
relative to the zero position of
the swivel range.
3 … 4
SIGNED16
-200 … +200
-200
1/10°
Oscillation fre-
quency
Common value for forward and
backward motion
5
UNSIGNED8
15 … 116
48
°/s
Table 10.44:
Parameters for module 64