Commissioning and configuration
Leuze electronic
BCL 504
i
141
TNT 35/7-24V
Parameter length
27 byte
Input data
None
Output data
None
Identifier string n (n = 1 … 5)
The identifier string defines both the identifier list for the segmentation and the passthrough
filter for the subsequent filtering.
The string may contain wildcards. That is, an arbitrary number of '?' are permitted as place-
holders for an arbitrary character at exactly that position.
Also permitted are '*' as placeholders for a character sequence of arbitrary length, and an 'x'
if the character at the respective position is to be deleted. There are a total of 5 identifier
strings.
An identifier with less than 5 characters must be null terminated. However, if the identifier
string consists of exactly 5 characters, it does not have to be null terminated.
10.10.2 Module 53 – Segmentation via fixed positions
Description
The module activates the segmentation via fixed positions. The parameters specify the iden-
tifiers to be searched for, the output mode, and the positions.
Parameters
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Identifier list
Identifier 1
The identifier string is used for the iden-
tifier list and the filtering according to
the segmentation.
0
STRING
5 characters
null terminated
1 … 5 bytes of
ASCII characters
‘*‘
-
Identifier 2
See identifier 1.
5
STRING
5 characters
null terminated
1 … 5 bytes of
ASCII characters
\0
-
Identifier 3
See identifier 1.
10
STRING
5 characters
null terminated
1 … 5 bytes of
ASCII characters
\0
-
Identifier 4
See identifier 1.
15
STRING
5 characters
null terminated
1 … 5 bytes of
ASCII characters
\0
-
Identifier 5
See identifier 1.
20
STRING
5 characters
null terminated
1 … 5 bytes of
ASCII characters
\0
-
Identifier output
Table 10.35:
Parameters for module 53