background image

 
 
                                                                                                                 

   

 

 

 

User’s Manual 

 
 
 
 

 

 
 
 
 

   

 

 

 

PIN & Proximity Card Reader 

 

 

 

Содержание iPASS IPK505

Страница 1: ...User s Manual PIN Proximity Card Reader ...

Страница 2: ...on 10 7 2 1 Termination Resistors 10 7 2 2 How To Connect Termination Resistors 11 7 2 3 Grounding System for Communication Cable 11 8 Installation 12 8 1 Installation of the Product 12 8 2 System Initialization 13 8 3 Wiring 13 8 3 1 Power 13 8 3 2 Output Connections 13 8 4 Wire Connection to Access Controller 14 9 Communication 14 9 1 RS232 Communiction Port Connection 14 9 2 RS422 Communication...

Страница 3: ...NG 21 12 1 2 COMMUNICATION ID ADDRESS DISPLAY 22 12 1 3 BAUD RATE SETTING 22 12 1 4 MASTER ID CHANGE 22 12 1 5 SYSTEM INITIALIZE 23 12 2 SETUP MENU F2 24 12 2 1 LCD DISPLAY SETTING 24 12 2 2 OUTPUT MODE SETTING 24 12 2 3 LED_BUZZER_CONTROL 25 12 2 4 FUNCTION KEY OUT 25 12 3 SETUP MENU F4 25 12 3 1 VERSION CHECK 25 12 3 2 LCD TEST 26 12 3 3 KEYPAD TEST 26 12 3 4 READER TEST 26 12 3 5 COMMUNICATION ...

Страница 4: ...ock when the unit is subsequently used 8 Unplug this product from the Direct Current DC power source and refer to qualified service personnel under these conditions a When the power supply cord or plug is damaged or frayed b If liquid has been spilled on the product c If the product does not operate normally after following the operating instructions in this manual Adjust only those controls that ...

Страница 5: ...Display on the LCD Dual Tamper Switches Wall Mount US EU Asian Gang Box Size Reverse Polarity Protection Options Supervisory Signal Compatible Controller 26bit Wiegand iCON100 iTDC Third Party Controller Standalone Controller 34bit Wiegand iCON100SR iTDC SR Third Party Controller Standalone Controller Comparison Table RFK505 Built in 125KHz 4 Proximity Reader IPK505 ASK EM Format Built in 125KHz 4...

Страница 6: ...s selectable RFK505 IPK505 26bit Wiegand ABA Track II 4 8bit Burst for PIN selectable Output Format SRK505U 34bit Wiegand ABA Track II 4 8bit Burst for PIN selectable LCD Character LCD 2Linges x 16Char 2 62 x 0 55 65 6mm x 13 8mm Screen Keypad 16 Key Numeric Keypad with Back Lighting LED Indicator 3 Array LED Indicators Red Green and Yellow Beeper Piezo Buzzer LCD 0 to 50 C 32 to 122 F Operating T...

Страница 7: ...number and current time on the LCD Setting Changes The Star RFK505 iPASS IPK505 IDTEKC SRK505U manages output mode setting external buzzer control and external LED control Keypad If the Star RFK505 iPASS IPK505 IDTEKC SRK505U is not connected to a host PC the integrated keypad and LCD display module can also be used for the entire programming process Product Explanation Front Panel Description 10 ...

Страница 8: ...ly by using the key pad Function key The unit has four Function keys F1 F2 F3 F4 Card reading status LED When a card is read the card reading status LED turns on green 6 2 2 Wire Color Table SIGNAL COLOR Main Power 12V Red Power Ground GND Black ABA Track II CP Out Orange Wiegand Data 0 Out ABA Track II Data Out Green Wiegand Data 1 Out ABA Track II Clock Out White Tamper Switch Out Purple with Wh...

Страница 9: ...nt before Installation election of Cable System installation cabling will be configured as follow RFK505 RFK505 Figure System Installation Layout ecommended Cable Type and Permissible Length Cable Reference Description Cable Specification Maximum Distance Controller Power DC12V DC Power Controller Belden 9409 18 AWG 2 conductor unshielded 30m Belden 9512 22 AWG 4 conductor shielded Reader Power an...

Страница 10: ...should be based on the cable length and data rate used by the communication system For example if you use 9 600 baud rate and 1 200m length of cable the propagation velocity of cable is 0 66 x speed of light This value is specified by the cable manufacturer if we assume the reflections will damp out in three round trip up and down the cable length the transmitted signal will stabilize 18 6us after...

Страница 11: ...f shield wires to the grounding system in this case there will be a current flow through the shield wire when the voltage level of both ends of shield wire is not equal and this current flow will create noise and interfere to communications For the good grounding we recommend to connecting ONLY one end of shield wire of communication cable to grounding system If you find earth ground nearby then c...

Страница 12: ...ation of the Product 8 1 1 Use the provided template to drill two 6 32 holes and one 1 2 hole on the proper location of the wall to mount the Wall Mount bracket as shown below Skip this step if the gang box is already installed on the wall 8 2 2 Using 2 screws install wall mount to the wall ...

Страница 13: ...the system power Then Initialize beep will be heard and picture will be displayed 1 System Initialize 1 Yes 0 No 2 4 System is Clear Remove Wires 3 System Initializing _ _ _ _ Master Password 1 For Hardware initializing enter key 1 2 Enter initial master password 3141 3 Showing initializing 4 After initializing Turn main power OFF and separate 3 wires and turn main power ON again 8 8 3 8 3 2 3 Wir...

Страница 14: ...ease follow the instructions Connect RS232 TX port of RFK505 to the pin 2 of the 9 pin connector Connect RS232 RX port of RFK505 to the pin 3 of the 9 pin connector Connect RS232 GND of RFK505 to the pin 5 of the 9 pin connector Plug in the 9 pin connector to COM1 or COM2 Port of the host PC Install and run RFK505 Application Software RS422 Communication Port Connection RS422 Connection SINGLE RFK...

Страница 15: ...5 Connect RS422 RX of one RFK505 to RS422 RX of another RFK505 Connect RS422 RX of one RFK505 to RS422 RX of another RFK505 Second you have to connect one of RS422 port of RFK505 to RS422 RS232 converter Connect RS422 TX of the one RFK505 to RX port of the converter Connect RS422 TX of the one RFK505 to RX port of the converter Connect RS422 RX of the one RFK505 to TX port of the converter Connect...

Страница 16: ...S MASTER ID YES ENTER SETUP MENU END SETTING YES NO SETTINGIN SETUP MODE INITIALIZE BEEP NO OUTPUT CONTROL OF EACH STATUS 10 1 INITIALIZATION OF RFK505 Before installation of the system and when it is not able to enter the setup menu system error or something wrong the user has to Hardware initialize The user has to initialize H W using an external reader port Turn off the system power and connect...

Страница 17: ...MENU If the user pressed ESC key RFK505 will be out of the SETUP MENU and returned to normal operation The user can also change the Master ID in the SETUP MENU F1 The Master ID for SRK505U is 10 times 0 key Default setting 0000000000 and default Master Password is 3141 11 Operation 11 1 11 2 D 11 2 1 WIE NORMAL OPERATION In usual power on the main lights on two red LED indicators of operating syst...

Страница 18: ...PE OUTPUT FORMAT 1 Data format for Card numbers Zero bit ID number 00000 65535 LRC Facility Code 1248P 00000 00255 low bit first odd parity last Start Character 11010 Hex B Zero bit 10bit 2 Data format for PIN Start Character 11010 Hex B PIN 1char to 8char low bit first odd parity last LRC Zero bit Zero bit 10bit ...

Страница 19: ...010 2 8 1000 8 3 0011 3 9 1001 9 4 0100 4 ESC 1010 A 5 0101 5 ENT 1011 B 8bit Burst output format Keypads Binary Hexa Keypads Binary Hexa 0 11110000 F0 6 10010110 96 1 11100001 E1 7 10000111 87 2 11010010 D2 8 01111000 78 3 11000011 C3 9 01101001 69 4 10110100 B4 ESC 01011010 5A 5 10100101 A5 ENT 01001011 4B Function key output format Keypads Binary Hexa Keypads Binary Hexa F1 00111100 3C F3 00011...

Страница 20: ...D BUZZER_CON 4 FUNC KEY OUT 1 F W VERSION 2 LCD TEST 3 KEYPAD TEST 4 READER TEST 5 COMM TEST To setup or to change the RFK505 IPK505 settings the user has to enter the SETUP MENU first To do so input Master ID Default setting 00000000 input Master Password Default setting 3141 and the user can get into SETUP MENU There are 4 main SETUP MENUs and the user first gets into SETUP MENU F1 The user can ...

Страница 21: ...EM INITIALIZE YES NO 4 or 6 key 4 or 6 key TIME SETTING 4 or 6 key TIME SETTING This displays current time To change time in current time press the ENT key In current status if you accurately enter to all information Year Month Day Hour Minute Second and Week setting is completed Above 15digit number should be inputted If out of range is inputted error message displays after inputting 15th week nu...

Страница 22: ...505 and host PC should be same If any communication problem please check as below Check COMM ID of RFK505 and host PC Check BAUD RATE of RFK505 and host PC Check communication port and cable Check COM port setup of host PC Parity None Data Bit 8 bit Stop Bit 1 bit To change the baud rate press ENT key and select desired baud rate by pressing 4 or 6 key then press ENT key BAUD RATE 9600 9600 BAUD R...

Страница 23: ... ID is finished successfully and soon will return to the first figure of this menu Master Card Registered 12 1 5 SYSTEM INITIALIZE SYS INITIALIZE Sys Initializing 1 Yes 0 No System Initializing This operation will initialize the RFK505 IPK505 SRK505 Press ENT key if an initialization is needed First time installation or resetting in the event of a malfunction CAUTION Initializing will erase all st...

Страница 24: ...AY STATUS This is LCD display setting menu The user can select whether LCD form is STATUS or CARD number STATUS Display status of reading ID CARD NO Display reading ID number OUTPUT MODE SETTING WIEGAND OUTPUT MODE This is output mode setting menu The user can select whether OUTPUT MODE is WIEGAND 4BIT BURST 8BIT BURST or ABA TRACK WIEGAND Outputs ID data through Wiegand output line 4BIT BURST Whe...

Страница 25: ...the unit green LED indicator is on for 3sec If master card isn t authorized its error is displayed by yellow LED indicator and buzzer sounds for 1sec LED_BUZZER_CON GL__ YL__ BZ__ FUNCTION KEY OUT This is set to use function key of the reader It is possible that function key is set to 4bit 8bit burst FUNC_KEY OUT 12 3 SETUP MENU F4 F W VERSION LCD TEST DISPLAY CURRENT F W VERSION KEYPAD TEST 4 or ...

Страница 26: ...referred to F1 F2 F3 F4 ESC and ENT key respectively KEYPAD TEST 0123456789ABCDEF READER TEST READER TEST Scanning Reader 1 XXXXXXXX Card No Reader No To test the performance of the reader press ENT key If RF card make the reader read it displays card and reader number of which card is read COMMUNICATION TEST COMM TEST To test the performance of input ports press ENT key Before this communication ...

Страница 27: ... the controller side Solution 1 Please check the settings of the application S W and the controller Check the controller s COMM ID is listed on the application S W Set the different COMM ID when two or more controllers are installed Check the communication speed Default 9600bps is the same as the setting on the S W Make sure that the PC s COM port is set correctly on the S W The parameters at the ...

Страница 28: ...the TX and TX lines and apply the same resistors to the converter RS422 lines Consult a service center or an electric technician if you cannot be sure how to do it 4 When a multi drop communication doesn t work test one by one communication first 5 If the trouble remains after the procedure above contact a designated service center ...

Страница 29: ...rsuant to Part 15 of the FCC Rules These limits are designed to this equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to r...

Страница 30: ... Fax 310 782 8298 E mail rflogics rflogics com Website www rflogics com Hong Kong Branch IDTECK Hong Kong 12 F B2B Centre No 36 Connaught Road West Hong Kong Tel 852 2581 9580 Fax 852 2234 5150 E mail alchu qala com hk Website www ristarhk com Please use the original container or pack the unit s in a sturdy carton with sufficient packing to prevent damage and include the following information 1 A ...

Страница 31: ...31 16 Template ...

Страница 32: ...ARK505HE1X The specifications contained in this manual are subject to change without notice at any time 5F Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Seoul 157 030 Korea Tel 82 2 2659 0055 Fax 82 2 2659 0086 E mail webmaster idteck com ...

Отзывы: