background image

 

 
 
 
 
 

DS6500 

 

INSTALLATION QUICK REFERENCE 

 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 

 

 
 

Содержание DS6500 Series

Страница 1: ...DS6500 INSTALLATION QUICK REFERENCE...

Страница 2: ...DS6500 100 012 ETHERNET MODEL 13 DS6500 100 015 DEVICENET MODEL 18 DS6500 105 0XX OSCILLATING MIRROR MODEL 23 COMMON FEATURES 25 NOTE For further details on product installation see the complete Refer...

Страница 3: ...che photodiode Wavelength 630 to 680 nm Power Consumption 15 W typical 20 W Max including startup current Main isolated Baud Rate Safety Class Class 2 EN 60825 1 Class II CDRH RS232 RS485 full duplex...

Страница 4: ...to C BOX100 10 m 93A051271 CAB 6101 Cable master slave 1 m 93A051220 CAB 6102 Cable master slave 2 m 93A051230 CAB 6105 Cable master slave 5 m 93A051240 CAB 6112 Cable master slave no power 2 m 93A05...

Страница 5: ...IN_REF Common reference of IN3 and IN4 polarity insensitive 9 13 VS Supply voltage positive pin 23 25 GND Supply voltage negative pin 14 1 25 13 25 pin male D sub Connector Pin RS232 RS485 Full Duplex...

Страница 6: ...ence Sensor connected to External Trigger PS input Pass Through Layout E N T E N T P S P S Gryphon DS4600A DS4600A DS6500 CAB 600X C BOX 100 C BOX 100 C BOX 100 AUX MAIN P S 2 2 1 1 Local Host 1 PWR 1...

Страница 7: ...ost 1 RS485 HD Main Interface P S Presence Sensor connected to External Trigger PS input RS232 Master Slave Layout E N T E N T DS6500 Master CAB 600X C BOX 100 DS4600A Slave 1 1 2 P S Local Host 1 C B...

Страница 8: ...d to accept scanner power Encoder connected to IN2 ENC input Local Lonworks Network Slave 2 Slave 1 Master C BOX 100 BTK 6000 CAB 610X CAB 610X CAB 600X P S CAB 610X Encoder Host CAB 610X CAB 610X CAB...

Страница 9: ...00 MASTER SLAVE MODEL Large Synchronized Network P S Presence Sensor connected to External Trigger PS input Encoder connected to IN2 ENC input Large Synchronized Network with DX6X00 and DS6XXX Scanner...

Страница 10: ...diode Wavelength 630 to 680 nm Power Consumption 15 W typical 20 W Max including startup current Main isolated Baud Rate Safety Class Class 2 EN 60825 1 Class II CDRH RS232 Laser Control Security syst...

Страница 11: ...to C BOX100 1 m 93A051221 CAB 6012 Cable to C BOX100 2 m 93A051222 CAB 6015 Cable to C BOX100 5 m 93A051223 C BOX 100 Passive connection box 93ACC1510 INT 30 20 mA C L interface board for C BOX 100 9...

Страница 12: ...ly voltage positive pin 23 25 26 GND Supply voltage negative pin 10 19 1 18 9 26 26 pin male D sub Connector Pin RS232 RS485 Full Duplex RS485 Half Duplex 20 mA C L INT 30 with C BOX 100 only 2 TX TX4...

Страница 13: ...sence Sensor connected to External Trigger PS input Pass Through Layout Remote Host E N T E N T P S P S Gryphon Fieldbus Network DS4600A DS4600A DS6500 CAB 601X C BOX 100 C BOX 100 AUX C BOX 100 P S 2...

Страница 14: ...Encoder CAB 610X CAB 610X CAB 63XX BTK 6000 Slave 3 Slave 5 Slave 4 PWR 240 CAB 63XX Fieldbus Small Synchronized Network P S Presence Sensor connected to External Trigger PS input C BOX 100 modified...

Страница 15: ...diode Wavelength 630 to 680 nm Power Consumption 15 W typical 20 W Max including startup current Main isolated Baud Rate Safety Class Class 2 EN 60825 1 Class II CDRH RS232 Laser Control Security syst...

Страница 16: ...to C BOX100 1 m 93A051221 CAB 6012 Cable to C BOX100 2 m 93A051222 CAB 6015 Cable to C BOX100 5 m 93A051223 C BOX 100 Passive connection box 93ACC1510 INT 30 20 mA C L interface board for C BOX 100 93...

Страница 17: ...N4A Input signal 4 polarity insensitive 24 IN_REF Common reference of IN3 and IN4 polarity insensitive 9 13 VS Supply voltage positive pin 23 25 26 GND Supply voltage negative pin 10 19 1 18 9 26 26 p...

Страница 18: ...sence Sensor connected to External Trigger PS input Pass Through Layout Remote Host E N T E N T P S P S Gryphon Fieldbus Network DS4600A DS4600A DS6500 CAB 601X C BOX 100 C BOX 100 AUX C BOX 100 P S 1...

Страница 19: ...Encoder CAB 610X CAB 610X CAB 63XX BTK 6000 Slave 3 Slave 5 Slave 4 PWR 240 CAB 63XX Fieldbus Small Synchronized Network P S Presence Sensor connected to External Trigger PS input C BOX 100 modified...

Страница 20: ...Wavelength 630 to 680 nm Power Consumption 15 W typical 20 W Max including startup current Main isolated Baud Rate Safety Class Class 2 EN 60825 1 Class II CDRH RS232 Laser Control Security system to...

Страница 21: ...able to C BOX100 1 m 93A051221 CAB 6012 Cable to C BOX100 2 m 93A051222 CAB 6015 Cable to C BOX100 5 m 93A051223 C BOX 100 Passive connection box 93ACC1510 INT 30 20 mA C L interface board for C BOX 1...

Страница 22: ...23 25 26 GND Supply voltage negative pin 10 19 1 18 9 26 26 pin male D sub Connector Pin RS232 RS485 Full Duplex RS485 Half Duplex 20 mA C L INT 30 with C BOX 100 only 2 TX TX485 RTX485 3 RX RX485 4 R...

Страница 23: ...esence Sensor connected to External Trigger PS input Pass Through Layout Remote Host E N T E N T P S P S Gryphon Fieldbus Network DS4600A DS4600A DS6500 CAB 601X C BOX 100 C BOX 100 AUX C BOX 100 P S...

Страница 24: ...X Encoder CAB 610X CAB 610X CAB 63XX BTK 6000 Slave 3 Slave 5 Slave 4 PWR 240 CAB 63XX Fieldbus Small Synchronized Network P S Presence Sensor connected to External Trigger PS input C BOX 100 modified...

Страница 25: ...oftware tool allows adjusting the linear motor speed oscillating frequency and the upper and lower limits of the oscillation by defining the top and bottom line limit angles When the oscillating mirro...

Страница 26: ...10 30 11 15 20 16 19 10 NOTE By limiting the raster width to the minimum necessary the number of scans on the reading surface is increased 24 Oscillating angles are selected in software where the mini...

Страница 27: ...sitive for Encoder 30 IN 2 ENC B polarity insensitive for Encoder 31 33 IN 3A polarity insensitive 32 34 IN 4A polarity insensitive 36 IN 3B IN 4B Reference polarity insensitive Outputs 21 OUT 1 22 OU...

Страница 28: ...ning them about half way 5 completely tighten the two screws on top of the head 6 completely tighten the four fixing screws Step A Head Feature 4 33 4 45 110 113 99 3 90 76 30 74 2 99 1 18 2 85 85 16...

Страница 29: ...uaranteed that the scanner reading performances see reading diagram section will match those measured for the standard installation with Skew angle between 10 20 NOTE The ST 210 mounting bracket is an...

Страница 30: ...1 1 5 2 2 5 3 0 25 8 9 11 13 15 17 5 7 8 10 11 13 0 30 8 10 12 14 16 18 6 7 9 10 12 13 0 33 9 11 13 14 16 18 6 8 9 11 12 14 0 38 10 11 13 15 17 19 7 8 10 11 13 14 0 50 12 13 15 17 19 21 8 9 11 12 14...

Страница 31: ...40 50 cm 60 20 24 80 32 in cm 0 10 20 30 8 12 4 0 40 16 50 20 10 4 20 8 0 25 mm 10 mils 0 3 mm 12 mils 90 36 100 40 70 28 40 16 50 20 30 12 0 375 mm 15 mils DS6500 105 0XX CONDITIONS Code Interleaved...

Страница 32: ...0 15 30 45 12 18 6 0 60 24 75 30 15 6 30 12 0 5 mm 20 mils 155 62 170 68 125 50 60 24 75 30 45 18 0 375 mm 15 mils DS6500 205 0XX CONDITIONS Code Interleaved 2 5 or Code 39 PCS 0 90 Pitch angle 0 Skew...

Страница 33: ...RTS 8 CTS 5 CTS How To Build A Simple Interface Test Cable The following wiring diagram shows a simple test cable including power external push button trigger and PC RS232 COM port connections 25 pin...

Страница 34: ...correct scanning speed The laser beam can be switched off through a software command see also the Genius Help On Line AVOID EXPOSURE LASER RADIATION IS EMITTED FROM THIS APERTURE AVOID EXPOSURE LASER...

Страница 35: ...O BEAM CLASS 3B LASER PRODUCT MAXIMUM OUTPUT RADIATION 35 mW EMITTED WAVE LENGTH 630 680 nm TO EN60825 1 2001 Laser Diode Class Label Any violation of the optic parts in particular can cause radiation...

Страница 36: ...product safety Bas e sur la l gislation des Etats membres relative la compatibilit lectromagn tique et la s curit des produits ber die Ann herung der Gesetze der Mitgliedsstaaten in bezug auf elektro...

Отзывы: