Table 4. DSA Preboot messages (continued)
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 8 “Parts listing, TD200 Machine Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836” on page
257 to determine which components are customer replaceable units (CRU) and which components are
field replaceable units (FRU).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a Trained service technician.
• Go to the Lenovo support Web site at http://www.lenovo.com/support/ to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Message
number
Component Test
State
Description
Action
201-801-xxx Memory
Memory Test
Aborted
Test canceled:
the system UEFI
programmed
the memory
controller with
an invalid CBAR
address
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the server firmware
is at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component. For
more information, see “Updating
the firmware” on page 306.
4. Run the test again.
5. If the failure remains, go to
the Lenovo Web site for more
troubleshooting information at
http://www.lenovo.com/support.
201-802-xxx Memory
Memory Test
Aborted
Test canceled:
the end address
in the E820
function is less
than 16 MB.
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that all DIMMs are
enabled in the Setup utility.
4. Make sure that the server firmware
is at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component. For
more information, see “Updating
the firmware” on page 306.
5. Run the test again.
6. If the failure remains, go to
the Lenovo Web site for more
troubleshooting information at
http://www.lenovo.com/support.
Chapter 5
.
Diagnostics
105
Содержание ThinkServer TD200
Страница 2: ......
Страница 8: ...viii ThinkServer TD200 Hardware Maintenance Manual ...
Страница 28: ...20 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 138: ...130 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 264: ...256 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 300: ...292 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 327: ...Lenovo product service Appendix A Getting help and technical assistance 319 ...
Страница 328: ...320 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 337: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix B Notices 329 ...
Страница 338: ...330 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 344: ...336 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 345: ......
Страница 346: ...Part Number Printed in USA 1P P N ...