1
Microprocessor
2
Retainer bracket
3
Heat sink release level
4
Alignment tab
5. Tilt the heat sink slightly to the side and slide the heat sink flange underneath the flange of the
heat sink retainer bracket.
6. Press down firmly on the heat sink until it is seated securely.
7. Rotate the heat-sink release lever to the closed position and hook it underneath the lock tab.
Step 8.
Reconnect any cables that you disconnected.
Step 9.
Install the air baffle (see “Installing the air baffle” on page 251).
Step 10. Rotate the power-supply cage assembly back into the server. Press the power-supply cage release
tab and rotate the power-supply cage assembly into the chassis.