• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 8 “Parts listing, TD200 Machine Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836” on page
257 to determine which components are customer replaceable units (CRU) and which components are
field replaceable units (FRU).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
Memory Logging Limit Reached
for DIMM All DIMMs on Memory
Subsystem All DIMMs.
Error
The memory logging limit has
been reached.
1. Update the server firmware to
the latest level.
Important:
Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code
is supported for the cluster
solution before you update the
code.
2. Reseat the DIMMs and run the
DSA memory test.
3. Replace any DIMM that is
indicated by a lit error LED.
Memory DIMM Configuration
Error for All DIMMs on Memory
Subsystem All DIMMs.
Error
A DIMM configuration error
has occurred.
Make sure that DIMMs are
installed in the correct sequence
and have the same size, type,
speed, and technology.
Memory uncorrectable error
detected for DIMM One of the
DIMMs on Memory Subsystem One
of the DIMMs.
Error
A memory uncorrectable
error has occurred.
1. If the server failed the POST
memory test, reseat the
DIMMs.
2. Replace any DIMM that is
indicated by a lit error LED.
Note:
You do not have to
replace DIMMs by pairs.
3. Run the Setup utility to enable
all the DIMMs.
4. Run the DSA memory test.
Memory Logging Limit Reached for
DIMM One of the DIMMs on Memory
Subsystem One of the DIMMs.
Error
The memory logging limit has
been reached.
1. Update the server firmware to
the latest level.
Important:
Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code
is supported for the cluster
solution before you update the
code.
2. Reseat the DIMMs and run the
DSA memory test.
3. Replace any DIMM that is
indicated by a lit error LED.
42
ThinkServer TD200 Hardware Maintenance Manual
Содержание ThinkServer TD200
Страница 2: ......
Страница 8: ...viii ThinkServer TD200 Hardware Maintenance Manual ...
Страница 28: ...20 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 138: ...130 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 264: ...256 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 300: ...292 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 327: ...Lenovo product service Appendix A Getting help and technical assistance 319 ...
Страница 328: ...320 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 337: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix B Notices 329 ...
Страница 338: ...330 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 344: ...336 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 345: ......
Страница 346: ...Part Number Printed in USA 1P P N ...