Automated boot recovery (ABR)
If the server is booting up and the IMM detects problems with the server firmware in the primary bank, it will
automatically switch to the backup firmware bank and give you the opportunity to recover the primary bank.
To recover to the server firmware primary bank, complete the following steps:
Step 1.
Restart the server.
Step 2.
When the prompt press
F3 to restore to primary
is displayed, press F3 to recover the primary bank.
Pressing F3 will restart the server.
Three boot failure
Configuration changes, such as added devices or adapter firmware updates can cause the server to fail
POST (power-on self-test). If this occurs on three consecutive boot attempts, the server will temporarily uses
the default configuration values and automatically goes to F1 Setup. To solve the problem, complete the
following steps:
Step 1.
Undo any configuration changes that you made recently and restart the server.
Step 2.
Remove any devices that you added recently and restart the server.
Step 3.
If the problem remains, go to the Setup utility and select
Load Default Settings
, and then click
Save
to restore the server factory settings.
Solving SCSI problems
Note:
This information also applies to Serial Attached SCSI (SAS) problems.
For any SCSI error message, one or more of the following devices might be causing the problem:
• A failing SCSI device (adapter, drive, or controller)
• An incorrect SCSI termination jumper setting
• A missing or incorrectly installed SCSI terminator
• A defective SCSI terminator
• An incorrectly installed cable
• A defective cable
For any SCSI error message, follow these suggested actions in the order in which they are listed until
the problem is solved:
1. Make sure that external SCSI devices are turned on before you turn on the server.
2. Make sure that the cables for all external SCSI devices are connected correctly.
3. If an external SCSI device is attached, make sure that the external SCSI termination is set to automatic.
4. Make sure that the last device in each SCSI chain is terminated correctly.
5. Make sure that the SCSI devices are configured correctly.
Solving power problems
Power problems can be difficult to solve. For example, a short circuit can exist anywhere on any of the
power distribution buses. Usually, a short circuit will cause the power subsystem to shut down because of
an overcurrent condition. To diagnose a power problem, use the following general procedure:
126
ThinkServer TD200 Hardware Maintenance Manual
Содержание ThinkServer TD200
Страница 2: ......
Страница 8: ...viii ThinkServer TD200 Hardware Maintenance Manual ...
Страница 28: ...20 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 138: ...130 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 264: ...256 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 300: ...292 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 327: ...Lenovo product service Appendix A Getting help and technical assistance 319 ...
Страница 328: ...320 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 337: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix B Notices 329 ...
Страница 338: ...330 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 344: ...336 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 345: ......
Страница 346: ...Part Number Printed in USA 1P P N ...