1
Power supply support bracket
2
Power supply release tab
Step 12. Install the side cover (see “Installing the side cover” on page 252).
Step 13. Lock the side cover.
Step 14. Reconnect the external cables and power cords; then, turn on the attached devices and turn on
the server.
Removing an adapter
To remove an adapter, complete the following steps.
Step 1.
Read the safety information (see Chapter 2 “Safety information” on page 3).
Step 2.
Turn off the server and all attached devices; then, disconnect all power cords and external cables.
Step 3.
Unlock and remove the side cover (see “Removing the side cover” on page 146).
Step 4.
Disconnect any cables from the adapter or any cables that impede access to the adapter.
Step 5.
Rotate the rear adapter retention bracket to the open (unlocked) position. If you are removing a
full-length adapter, open the front adapter-retention bracket also.
Step 6.
If necessary, remove the expansion-slot screw at the rear of the adapter.
Step 7.
Carefully grasp the adapter by its top edge or upper corners, and pull the adapter from the server.
Attention:
Expansion-slot covers must be installed in all empty slots. This maintains the electronic
emissions standards of the computer and ensures proper ventilation of computer components.
Chapter 7
.
Installing and replacing FRUs
217
Содержание ThinkServer TD200
Страница 2: ......
Страница 8: ...viii ThinkServer TD200 Hardware Maintenance Manual ...
Страница 28: ...20 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 138: ...130 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 264: ...256 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 300: ...292 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 327: ...Lenovo product service Appendix A Getting help and technical assistance 319 ...
Страница 328: ...320 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 337: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix B Notices 329 ...
Страница 338: ...330 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 344: ...336 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 345: ......
Страница 346: ...Part Number Printed in USA 1P P N ...