1
DIMM 1 (reserved)
9
DIMM 9 (reserved)
2
DIMM 2
10
DIMM 10
3
DIMM 3
11
DIMM 11
4
DIMM 4 (reserved)
12
DIMM 12 (reserved)
5
DIMM 5
13
DIMM 13
6
DIMM 6
14
DIMM 14
7
DIMM 7
15
DIMM 15
8
DIMM 8
16
DIMM 16
.
Attention:
To avoid breaking the DIMM retaining clips or damaging the DIMM connectors, open
and close the clips gently.
Step 8.
Carefully open the retaining clips on each end of the DIMM connector and remove the DIMM.
1
DIMM
2
Retaining clip
Step 9.
If you are instructed to return the DIMM, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.
Installing a memory module
Note:
If you are replacing a faulty DIMM, make sure that the replacement DIMM is the correct type of
memory. If you are adding DIMMs, install the DIMMs in the sequence indicated in this section.
The following notes describe the types of dual inline memory modules (DIMMs) that the server supports and
other information that you must consider when installing DIMMs (see “System-board option connectors” on
page 137 for the location of the DIMM connectors):
• The server supports industry-standard, 800, 1066, or 1333 MHz, PC3-10600R-999 (single-rank or
dual-rank) double-data-rate 3 (DDR3), registered, synchronous dynamic random-access memory
(SDRAM) dual inline memory modules (DIMMs) with error correcting code (ECC). For a list of supported
Chapter 7
.
Installing and replacing FRUs
211
Содержание ThinkServer TD200
Страница 2: ......
Страница 8: ...viii ThinkServer TD200 Hardware Maintenance Manual ...
Страница 28: ...20 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 138: ...130 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 264: ...256 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 300: ...292 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 327: ...Lenovo product service Appendix A Getting help and technical assistance 319 ...
Страница 328: ...320 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 337: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix B Notices 329 ...
Страница 338: ...330 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 344: ...336 ThinkServer TD200 Hardware Maintenance Manual ...
Страница 345: ......
Страница 346: ...Part Number Printed in USA 1P P N ...