OMEGA
Installation Manual
Edition February
2020
Omega
platform lift
page 27 of 52
Options
Menu item
Parameter
Meaning
Description
Opening
behaviour
ON
Special folding
modus
If this is ON the security circuit on
the drive unit will be checked. If this
is open the unit also will not fold.
OFF
Standard folding
modus
Auto-close
ON
Automatic closing
ON
If this parameter is ON then the
platform will close automatically
after a defined time if left open in a
landing station.
Attention: Only possible for
automatic and not for manual
platforms
OFF
Automatic closing
OFF
Auto-close time
seconds
Time to fold
automatically
Defines time lag for auto-fold
Middle time
Second
Time of middle
stop
Time that allows for releasing and
pressing again of direction button to
continue driving out of intermediate
landing
Call open
ON
Call and send the
platform when
open
If this parameter is on then the
open platform can be call and sent
by the external hall call stations
(when transporting goods)
Attention: This option can only be
chosen if the entire driveway of the
platform is totally visible from the
hall call stations.
OFF
Not permitted
S Error behav
Value 1…3
Automatic reset of short circuit error
14 and 15 in landing station
Adv error reset
ON
Reset of error
Automatic reset of tolerance error 1,
6, 7, 8, 14 and 15 in landing station
OFF
Error needs to be acknowledged
Parkstop
ON / OFF
Set start stop ON to programme
Parkstop start
Start of parkstop drive (for example
upper landing stop)
Parkstop stop
Stop of drive (park position)
Parkstop closed
ON / OFF
Allows only to drive closed into park
stop