Buttons and Jumpers
On the drive unit control board different buttons and jumpers are located that control
different functions as listed below:
Button S1
This button has 2 different functions depending on type of operation modus:
1. Standard use (work modus): Button used to acknowledge failures indicated on
display
2. Emergency use (emergency modus): As a security measure this button has to be
pressed in order to be able to drive the unit in emergency use. See page 38.
Button S2
Is used to teach the radio controls senders.
Jumper J1
This jumper controls the operation modus. The following 2 jumper positions are possible.
Please note that no other than these 2 positions can be active, otherwise the board can be
damaged.
Standard operation
Emergency operation
Jumper J6
With this jumper the voltage type for the main contactors can be set, depending on the type
of main contactors used. Wrong jumper position can damage the board!
DC version
AC version