Step 7. Mounting the mechanical stop station assembly
Adjust the position of the control cam in reference to the limit switch device on the
rail. The bypass switch has to be activated
before
the levers for unblocking of the
barrier arms touch the control cams on the rail.
Levers for
unblocking of the
barrier arms at
the upper and
lower control cam
Bypass switch
S16 and lever
Landing stop
switches