OMEGA
Installation Manual
Edition February
2020
Omega
platform lift
page 18 of 52
Tube and
earth wire
Tension
rope wire
Current
Donator
Ultimate upper
limit switch
Main power
switch
Step 6: Electrical connections
Connection the tension rope and the rail from the current collector, and the support
rope to the platform control board as described on the previous page.
Connect the tension rope wire from the drive
unit control board to the current donator on
the drive wheel and also connect the earth
and the tube wire to the rail next to the
current donator.
Connect the upper ultimate
limit switch to the drive unit
control board – connector
name “NESO”.
Connect the on-site main
power supply to the main
power switch on the drive
unit.