OMEGA
Installation Manual
Edition February
2020
Omega
platform lift
page 33 of 52
Motor
temperature
Fire alarm contact
(optional)
13 (d)
Ride to the next
stop position
The thermal contact in the drive
motor has tripped or the fire alarm
contact has tripped (optional).
An approach from the stop position is
no longer possible as long as the
signal is present.
Short circuit
between traction
rope and tube
14 (E)
Ride to the next
stop position,
provided that the
short circuit is no
longer present
This error occurs if there is still a
short circuit between the traction
rope and the tube after five restart
attempts.
An approach from the stop position is
no longer possible as long as the
signal is present.
Short circuit
between support
rope and tube
15 (F)
Ride to the next
stop position
When a short circuit occurs between
the support rope and the tube.
An approach from the stop position is
no longer possible as long as the
signal is present.
This error also occurs when the
resistor RV on the platform is not
properly connected or has a
resistance of about 50 ohms.
Following error Safety switch
triggered
Rocker makes short
circuit
SPI timeout drive
16 (1.)
Ride is
interrupted
The communication between the PIC
microcontroller and the Echelon
Powerline module was faulty.
Powerline module defective.
Safety circuit
17 (2.)
Ride to the next
stop position
Safety Circuit Relay on platform
board (KFahrAUF1, KFahrAB1)
Contact is stuck.
FI communication 18 (3.)
Only slow ride
The communication with the
frequency inverter via the RS485
interface (Modbus) has failed.
Communication
with EEPROM
drive
19 (4.)
-
The communication of the
microcontroller with the EEPROM
located on the drive board failed, or
memory location in EEPROM could
not be written correctly.