OMEGA
Installation Manual
Edition February
2020
Omega
platform lift
page 32 of 52
Outside the valid
range
5 (5)
Only slow ride
The error occurs when the number of
pulses reaches an invalid value (e.g.,
less than 0).
This can happen if you push the
lower limit switch anywhere on the
track and then continue downwards
again.
Upon pressing of the lower limit
switch, the pulse value is set to e.g.
160, the pulse values are reduced
and a value less than 0 can occur
when moving further down.
Tolerance field
error at end stop
position
6 (6)
Only slow ride
If, during normal travel, the counted
pulses deviate too much from the
stored pulse values.
The reason may be that the limit
switch curves were adjusted after the
learn trip.
Tolerance field
error intermediate
stop position
7 (7)
Only slow ride
If, during normal travel, the counted
pulses deviate too much from the
stored pulse values.
The cause may be that the limit
switch curves of the intermediate
stops were adjusted after the learn
trip
Pulse at stop
position
8 (8)
Only slow ride
If during normal ride more than a
certain number of pulses occur as
long as the limit switch is pressed.
Mostly a sign that a limit switch is
stuck.
Wrong direction
of rotation
10 (A)
Only slow ride
If the pulse generator returns a
different direction than the one output
from the inverter.
Brake weak
11 (b)
Only slow ride
If the ride command is interrupted
and the pulse generator continues to
count a certain number of pulses,
this is an indication that the brake
does not stop the lift correctly.