Dismantle the platform floor
Dismantle the ball bearing connection between sliding mechanism and platform
Disconnect platform rod connection for sidewall
Dismantle safety under-pan of the platform
Disconnect spring inside platform floor. You might need to manually compress the
spring in order to uninstall the connection. Make sure that the connection between
the spring and the bearing is correctly put together afterwards. The connection metal
parts have a slight bend. It is important for reassembly that they are put back in the
same way.
Disconnect the electrical wiring between the platform floor and the sidewall
Disconnect fixing screw from the treaded pinhole of main platform hinge bearing
Remove the main bearing pin and take off the platform floor
Take out main
bearing pin
Disconnect spring
Disconnect platform rod
Loosen ball bearing
Take out spring
Disconnect fixing
screw and wiring
Bend in metal part