Page 7
Conventional use
• is solely fit for compressing and drying purified air to be supplied to cables.
• shall only be used for the purposes validated by LANCIER Monitoring.
• shall only be operated under the conditions stipulated in this operating instruction.
• shall only be operated with the settings and variants stipulated in this operating instruction.
The automatic operation of the system permits unsupervised, steady use.
Any other use is not classed as conventional. The manufacturer takes no responsibility for any resulting
damages. The operator alone bears the risks!
Arbitrary changes in design or system rebuild are prohibited without the written consent of the manufacturer,
as are modifications and interventions in the control programme, the compressors and settings of the drying
process, as well as the pressures used.
Compliance with the stipulated operating, servicing and repair conditions also form part of conventional use.
Safety instructions
Important!
It is imperative to read and observe the safety instructions prior to start up.
The operating instruction must always be stored within reach.
For the safety of persons in charge
Operator
Operator is any natural or legal person, who uses the equipment or on whose instructions the equipment is
used.
The operator or his safety officer must guarantee, that
• all relevant regulations, references and laws are adhered to.
• only qualified employees work on and with the equipment
• employees have the operating instruction available during all works and abide by this.
• non-qualified employees are forbidden from working on and with the equipment, as well as installation and
servicing. The necessary accident prevention and safety instructions must be are adhered to.
Qualified employees
Qualified employees are persons who are authorised by the person in charge for equipment safety based on
their training, experience, instruction and knowledge on relevant standards and provisions, accident prevention
regulations and operating conditions, to carry out operations required and be able to identify and prevent pos-
sible dangers.
Staff qualification
Briefed person
Operations
Briefed person
with technical training
Electro specialists
Initial commissioning
-
-
✔
Operation
✔
✔
✔
Fault repair
- mechanic
-
✔
✔
- electrical
-
-
✔
Cleaning
✔
✔
✔
Servicing
-
✔
✔
Work on the electrics
-
-
✔
Packaging / transportation
✔
✔
✔
Содержание RTS 1000
Страница 15: ...Page 15 39 35 37 36 36 23 42 28 27 24 6 33 38 40 41 32 22 29 25 8...
Страница 21: ...Page 21...
Страница 47: ...Page 47 7 16 14 15 15 18 17 13 20 24 8 23 10 6 9 4 22 21 19 8...
Страница 51: ...Page 51 Pneumatics diagram Nr 074891 000...
Страница 53: ...Page 53 Circuit diagram Nr 074880 000...
Страница 55: ...Wiring diagram Nr 074881 000 Page 55...