Page 18
Mounting
The pressurisation system RTS 1000 is designed to be
located at floor level or mounted to a wall. The floor must be
constructed for exposure to dynamic stresses and strains.
LANCIER Monitoring assumes no liability whatsoever for wall
mounting.
The place of mounting should be dry and swept clean.
Minimum distance to adjacent walls and equipment
= 500 mm
The pressurisation system RTS 1000 must be placed in a way
that avoids moving around due to vibrations.
Connect the diffusor condensate discharge hose (10)
• discharges the condensat of the air dryers (
35
)
• the diffusor at the end of the hose sprays the condensate into
the ambient air.
• At normal conditions a condensate storage tank is not nee-
ded.
10
Electrical connection
Deadly risk!
Electrical connection must only be made by electrical specialists!
After connecting electricity: Take caution with live components!
Operating voltage 230 V AC
• Before connection to the mains supply mind that the power
supply voltage complies with the operating voltage of the com-
pressor (
8
) (see compressors name plate)!
• The following security relevant elements must be supplied for
electrical connection:
-
main switch with emergency stop function
according to IEC/EN60204-1, VDE 0113 Part 1
11
-
nominal voltage
230 V one phase / 400 V three phases, neutral and grounding conductor
-
overcurrent protection device
for each phase maximum 16 A (lead fuses or circuit breaker characteristic B)
-
residual-current-operated protective device
(RCD)
• Plug in electrical plug (
11
) into power socket
Содержание RTS 1000
Страница 15: ...Page 15 39 35 37 36 36 23 42 28 27 24 6 33 38 40 41 32 22 29 25 8...
Страница 21: ...Page 21...
Страница 47: ...Page 47 7 16 14 15 15 18 17 13 20 24 8 23 10 6 9 4 22 21 19 8...
Страница 51: ...Page 51 Pneumatics diagram Nr 074891 000...
Страница 53: ...Page 53 Circuit diagram Nr 074880 000...
Страница 55: ...Wiring diagram Nr 074881 000 Page 55...