Page 39
Change micro filter element of micro filter
Deadly risk!
Switch off operating voltage!
Risk of injury!
Prior to operation, depressurise the equipment by opening the safety valve „high pressure” (29)!
Change micro filter element (88) of micro filter (37)
- when the UMS monitoring system indicates that the compressor’s pressure is reaching the maximum
admissble limit,
- after changing drying agent of the drying agent containers (
35
) (see page 40).
• Detach micro filter:
Remove filter cup (
85
) by loosening the connecting nut from
the filter head (
86
).
• Unfasten hollow grub screw (
87
) with micro filter element (
88
).
• Remove micro filter element (
88
) and replace with new one.
• Clean seal (
89
), if necessary replace worn seal.
• Screw hollow grub screw (
87
) together with micro filter ele-
ment (
88
) and seal (
89
) again into the filter head (
86
).
• Clean filter cup (
85
), keep dust-free.
• Attach filter cup (
85
) by tightening the connecting nut on
the filter head (
86
).
89
85
87
88
90 86
Содержание RTS 1000
Страница 15: ...Page 15 39 35 37 36 36 23 42 28 27 24 6 33 38 40 41 32 22 29 25 8...
Страница 21: ...Page 21...
Страница 47: ...Page 47 7 16 14 15 15 18 17 13 20 24 8 23 10 6 9 4 22 21 19 8...
Страница 51: ...Page 51 Pneumatics diagram Nr 074891 000...
Страница 53: ...Page 53 Circuit diagram Nr 074880 000...
Страница 55: ...Wiring diagram Nr 074881 000 Page 55...