Page 54
Equipment list electrics
A1
Humidity monitoring unit 1
A2
Humidity monitoring unit 2
A3
Humidity monitoring unit 3
A4
Control unit
A5
Flow meter - Printed circuit board RTS
A6
Flow meter - Integral part
B1
Pressure switch "high pressure"
B2
Pressure switch "Cable pressure (1) too low"
B3
Pressure switch "Cable pressure (1) too high"
B4
Pressure switch "Cable pressure 2 too low"
B5
Pressure switch "Cable pressure 2 too high"
B6
Pressure switch "Add compressor 2"
C1
Capacitor
E1
Fan 1
E2
Fan 2
E3
Fan 3
F1
Motor protective relay 1
F2
Motor protective relay 2
F3
Motor protective relay 3
F4
Thermal protection
F6
Pressure monitor
F7
Fuse
F8
Overvoltage suppressor
G1
Power pack 1
G2
Power pack 2
G3
Power pack 3
G4
Battery
G5
Battery charger
G6
Bridge rectifier
H1
Signal-LED "AC"
H2
Signal-LED "DC"
H3
Signal-LED "F"
H4
Signal-LED "H"
H5
Signal-LED "M"
H6
Signal-LED "T"
H7
Signal-LED "N" (or "N1")
H8
Signal-LED "N2"
H9
Signal-LED "W"
H10
Signal-LED "K" (or "K1")
H11
Signal-LED "K2"
H12
Signal-LED "G"
H13
Signal-LED "A"
H14
Signal-LED "Fault"
H15
Signal-LED "Signal interruption"
K1
Contactor - Compressor 1
K2
Contactor - Compressor 2
K3
Contactor - Compressor 3
K4
Power failure relay AC
K5
Signal relay "K"
K6
Humidity detector relay 1
K7
Humidity detector relay 2
K8
Humidity detector relay 3
K9
Time relay "Running time"
K10
Signal relay "T"
K11
Signal relay "A"
K12
Signal relay "F"
K13
Signal relay "M"
K14
Signal relay "H"
K15
Signal relay "N"
K16
Time relay "8 min" 1
K17
Time relay "8 min" 2
K18
Switch clock
K19
Switching relay
K20
Signal relay "W"
K21
Time relay "Backlash"
K22
Switching relay
K23
Signal relay "V"
M1
Motor - Compressor 1
M2
Motor - Compressor 2
M3
Motor - Compressor 3
M4
I.C.-engine
P1
Counter of operation hours - Compressor 1
P2
Counter of operation hours - Compressor 2
P3
Counter of operation hours - Compressor 3
P4
Hygrometer 1
P5
Hygrometer 2
P6
Hygrometer 3
P7
Counter of operation hours 1 with maintenance signal
P8
Counter of operation hours 2 with maintenance signal
P9
Counter of operation hours 3 with maintenance signal
P10
Voltmeter
Q1
Main switch AC
Q2
Main switch DC
Q3
Fused DC main switch DC
Q4
Motor protective switch 1
Q5
motor protective switch 2
Q6
motor protective switch 3
S1
Programme switch 1
S2
Programme switch 2
S3
Programme switch 3
S4
Switch "F-aus" 1
S5
Switch "F-aus" 2
S6
Switch "F-aus" 3
S7
Change-over switch
S8
Door switch
S9
Key "W-Test"
V
Diode
X1
Connecting block 1
X2
Connecting block 2
X3
Connecting block 3
X4
Connecting block 4
X5
Connecting block 5
X6
Power socket
Y1
3/2 way solenoid valve - Dryer 1
Y2
3/2 way solenoid valve - Dryer 2
Y3
4/2 way solenoid valve - Dryer 1
Y4
4/2 way solenoid valve - Dryer 2
Y6
Humidity stop solenoid valve
Y7
Non-return solenoid valve block
Y8
Solenoid valve - Aeration
Short symbol for signals
AC
= Operation AC
DC
= Operation DC
F
= Humidity
H
= High-pressure
M
= Compressor failure
T
= Running time
N (or N1) = Cable pressure (1)
N2
= Cable pressure 2
W
= Maintenance
A
= Fault
G
= Cable filled
K (or K1) = Cable fault (1)
K2
= Cable fault 2
S
= Fuse
V
= Power failure AC
Содержание RTS 1000
Страница 15: ...Page 15 39 35 37 36 36 23 42 28 27 24 6 33 38 40 41 32 22 29 25 8...
Страница 21: ...Page 21...
Страница 47: ...Page 47 7 16 14 15 15 18 17 13 20 24 8 23 10 6 9 4 22 21 19 8...
Страница 51: ...Page 51 Pneumatics diagram Nr 074891 000...
Страница 53: ...Page 53 Circuit diagram Nr 074880 000...
Страница 55: ...Wiring diagram Nr 074881 000 Page 55...