PIKO 3.6 MP
PIKO 4.2 MP
AC connection
Type
Wieland RST25i3 plug
Connection conductor cross-section
Cable diameter 10 ... 14 mm
2
, conductor cross-section ≤
4 mm
2
Opposing connector
Opposing connector included in delivery
Dimensions (X x Y x Z)
340 x 608 x 222 mm
Weight
9.1 kg
Display
Graphical display, 128 x 64 pixels
Communication interfaces
RS485 (2 x RJ45 sockets: Anschluss an Meteocontrol WEB‘log
oder Solar-Log™, 1 x RJ10 Buchse: Connection to Modbus
RTU counter), Ethernet interface (1 x RJ45)
Feed-in management as per
EEG 2012
EinsMan-ready, via RS485 interface
Integrated DC circuit breaker
yes, compliant with VDE 0100-712
Cooling principle
Temperature-controlled fan, speed variable, internal (dust-pro‐
tected)
Test certificate
Certificates download see the product page on our homepage.
Technical data at 25 °C/77 °F
1)
Due to its design the inverter cannot cause any DC fault currents.
9.2 AC cables and line circuit breakers
Tab. 4:
Conductor cross-sections of the AC cables and suitable line circuit breakers
Inverter
AC cable conductor cross-
section
Power loss
1)
Miniature circuit
breaker
PIKO 1.5 MP
1.5 mm
2
10 W
B16
2.5 mm
2
6 W
B16
4.0 mm
2
4 W
B16
PIKO 2.0 MP
1.5 mm
2
18 W
B16
2.5 mm
2
11 W
B16
4.0 mm
2
6 W
B16
PIKO 2.5 MP
2.5 mm
2
16 W
B16
4.0 mm
2
11 W
B16
Technical data
11/2017 | DOC01664604 | KOSTAL operating instructions PIKO inverter 1.5 - 4.2 MP
73