PIKO 1.5 MP
PIKO 2.0 MP
Efficiency change in the case of devia‐
tion from the DC rated voltage
0.002 %/V
Own consumption
< 4 W
Derating at full power
from 50 °C (T
amb
)
Switch-on power
10 W
Switch-off power
5 W
Safety
Protection class according to IEC
62103
II
Isolation principle
No electrical isolation, transformer-less
Grid monitoring
yes, integrated
Insulation monitoring
yes, integrated
Residual current monitoring
yes, integrated
1)
Overvoltage protection version
Varistors
Reverse polarity protection
yes
Operating conditions
Area of application
Indoor rooms, with or without air conditioning
Climate protection class as per IEC
60721-3-3
3K3
Ambient temperature range
–15 °C ... +60 °C
Storage temperature
-30 °C ... +80 °C
Relative humidity
0 % ... 95 %, non-condensing
Operating altitude above sea level
≤ 2000 m above sea level
Pollution degree
PD3
Noise emission (typical)
31 dBA
Improper ambient gases
Ammonia, solvents
Fittung and construction
Protection class
IP21 (housing: IP51; display: IP21)
Overvoltage category
III (AC), II (DC)
DC connection
Type
Phoenix Contact SUNCLIX (1 pair)
Connection conductor cross-section
Conductor cross-section 2.5 … 6 mm²
Opposing connector
Opposing connector included in delivery
Technical data
11/2017 | DOC01664604 | KOSTAL operating instructions PIKO inverter 1.5 - 4.2 MP