5.
Disconnecting the AC plug from the inverter
⇒
Release safety clip at
the front of the AC plug by depressing it with a suitable object, then
pull the plug out.
6.
Check that all pins of the AC plug are free of voltage. Use a suitable
voltmeter for this (do not use a simple neon phase checker).
NOTICE!
Risk of damage to the inverter or derating!
–
The mounting location must satisfy the following condi‐
tions:
–
The mounting location and immediate environment
are permanently fixed, vertical, flat, non-inflammable
and not subject to constant vibration.
–
The permissible ambient conditions are complied
Chapter 9 „Technical data“ on page 63
–
The following free spaces must be present around
the inverter:
Above/below: at least 200 mm
At the sides/in front: at least 60 mm
–
Do not install the inverter in areas where animals are
kept.
–
Observe the connection ratings specified on the type
plate.
–
The DC cables must not be connected to an earth
potential (DC inputs and AC output are not galvanically
isolated).
NOTICE!
When transmitting data over a public network:
–
Transmitting data over a public network may result in
additional costs.
–
Data transmitted over a public network is not protected
from unauthorised access by third-parties.
NOTICE!
–
Avoid exposing the inverter to direct sunlight.
–
The display must be readable on the installed device.
Installation
11/2017 | DOC01664604 | KOSTAL operating instructions PIKO inverter 1.5 - 4.2 MP
31
Содержание PIKO 1.5 MP
Страница 1: ...PIKO 1 5 4 2 MP Operating instructions...
Страница 77: ...Appendix Appendix 11 2017 DOC01664604 KOSTAL operating instructions PIKO inverter 1 5 4 2 MP 77...
Страница 79: ......