RA83/84/85/93/94/95 Series
Chapter 6
Using The Menu
Operation Manual
6.4.3 BITE (Built In Test Equipment)
NOTE:
This menu is protected from ordinary operations. To use this function, turn off the
radar first. Press and hold the MODE key and turn the radar on. When the standby condition
is established, turn the radar on to enter the following menu functions.
6.4.3.1
ALARM TEST (Alarm System Test)
This function is used to verify that the alarm function is in normal order.
Indication
Meaning Selection
ALARM TEST
Alarm
System
Test
OFF, ON
Carry out the following operation to perform this function.
(1) Highlight the words ALARM TEST.
(2) Press the ENT key to set the selection ready status.
(3) Press the joystick down to select the ON sign.
(4) Press the ENT key to fix the selection. The alarm test will start.
(5) In approximately 10 seconds, various alarm messages will be shown and an audio
alarm will be activated. (NOTE: NO audio alarm sounds if the BUZZER OFF status
is activated)
(6) To cancel the ALARM TEST function, set the ALARM TEST to OFF, or set the
radar to standby mode once, and then transmit again.
6.4.3.2
ATA TEST (ATA Tracking Test Mode)
This function is used to test the ATA function.
Indication
Meaning
Selection
ATA TEST
ATA Tracking Test Mode
OFF, ON
When the ATA Test mode is selected, the following test conditions and display will be
available on the screen.
(1) Range scale: 6 NM
(2) Ship’s heading: 90 degrees
(3) Test target speed: 12 knots
(4) Test target bearing: 90 degrees
(5) A small letter “x” will be shown near the test target as an identifier and a large letter
“X” at the bottom of the screen, showing that the display is in the TEST mode.
93142105-02
6-21