2.2.2
Setup Software
Fiber Optic Cable Length
If the optical power is not adjusted properly, there will be errors in the telegram transmis-
sion. You can define the cable length (in meter) for a standard 1 mm² fiber optic cable.
0 m
Very short connection
1 m…< 15 m
Length of the connection with a 1 mm² plastic cable
15 m…<30 m
Length of the connection with a 1 mm² plastic cable
³
30 m
Length of the connection with a 1 mm² plastic cable
Baud Rate
If the baud rate is not adjusted correctly, communication will not work. Adjust the baud
rate in MBaude here.
Address
The actual amplifier address is indicated (setting see p.14).
Phase
The actual phase of the sercos
®
transmission is indicated.
Cycle time
Actual cycle time is indicated.
Monitor IDN
No
.
Enter an IDN here, which is then cyclically updated (example: to watch IDNP 3036 the
number has to be 3036). This is used as the internal “service channel”.
Value
The value of the monitored IDN. For IDNs that contain lists, only the list length is dis-
played.
sercos
®
for S300/S700
17
Kollmorgen
04/2016
Installation / Setup