3.124
IDN185 Maximum Length of AT Configurable Data
Defines the maximum length, in bytes, of the AT’s cyclic data field. The master may use
this IDN to determine how many IDNs may be placed within the application telegram
(refer to IDN15).
Data Length: 2 bytes
Non-Volatile:
Fix
Data Type:
Unsigned decimal
Write Access:
Read-only
Minimum:
Run-Up Check:
Maximum:
Cyclic Transfer:
Default:
24
ASCII Param.:
Units:
Bytes
Version:
3.125
IDN186 Maximum Length of MDT Configurable Data
Defines the maximum length, in bytes, of the MDT’s cyclic data field. The master may use
this IDN to determine how many IDNs may be placed within an application telegram (refer
to IDN15).
Data Length: 2 bytes
Non-Volatile:
Fix
Data Type:
Unsigned decimal
Write Access:
Read-only
Minimum:
Run-Up Check:
Maximum:
Cyclic Transfer:
Default:
12
ASCII Param.:
Units:
Bytes
Version:
68
sercos
®
for S300/S700
sercos
®
IDN Set
04/2016
Kollmorgen