10.4.2 Additional fault messages AKD-T
AKD BASIC runtime faults are displayed in the two-digits 7-segment display of the drive:
The two digits LED display
indicates the fault code.
The additional runtime fault messages for AKD-T are coded with numbers starting from F801.
Remedy for all errors: clear error, fix user program, recompile, download and attempt to run
the program again.
Eliminate errors and faults in compliance with work safety rules. Troubleshooting only by
qualified and trained staff.
More information about error messages, causes, remedy and clearing errors can be found in
the WorkBench online help and in
.
Error
Description
F801
Divide by zero.
F802
Stack Overflow.
F803
Insufficient Memory.
F804
No interrupt handler defined.
F805
Interrupt error.
F806
Max string length exceeded.
F807
String overflow.
F808
Array out of bounds.
F809
Feature not supported.
F810
Internal firmware/hardware error.
F812
Parameter not supported.
F813
Parameter access error.
F814
Data not found.
F815
Data invalid.
F816
Data too high.
F817
Data too low.
F818
Param type out of range.
F819
Data not divisible by 2.
F820
Invalid position modulo setting.
F821
Cannot read from command.
F823
Enable Drive first.
F824
DRV.OPMODE must be 2 (position).
F825
DRV.CMDSOURCE must be 5 (program).
F826
Cannot execute during a move.
F827
Writing to read-only parameter.
F828
Disable Drive first.
F829
Opcode not supported - upgrade firmware.
F830
No negative values allowed.
F831
BASIC program is invalid. May need firmware upgrade.
F832
BASIC program is missing.
F901
Too many cams.
AKD Installation | 10 Setup
Kollmorgen | kdn.kollmorgen.com | October 2017
207
Содержание AKD series
Страница 162: ...AKD Installation 9 Electrical Installation Wiring diagram X24 162 Kollmorgen kdn kollmorgen com October 2017 ...
Страница 179: ...9 20 6 CAN Bus Wiring AKD Installation 9 Electrical Installation Kollmorgen kdn kollmorgen com October 2017 179 ...
Страница 214: ... AKD Installation 11 Index 214 Kollmorgen kdn kollmorgen com October 2017 ...