AKD Installation | 9 Electrical Installation
9.12.10.2 Connection to X9 and X8
The thermal control in the motor is connected via Analog I/O on X8 and evaluated in the drive.
All signals are connected using our special connection cable (Europe: CFD5).
Analog I/O functionality must be selected in the related WorkBench screen. If the set limit is
exceeded, then warning n256 is created.
If cable lengths of more than 50 m are planned, please consult customer support.
Type
FB3.MODE
Frequency Limit
Description
ENDAT 2.2
0*
2,5 MHz
Adjust on screen page FEEDBACK
* For use as primary motor feedback, set parameters DRV.EMUEMODE, PL.FBSOURCE,
IL.FBSOURCE, VL.FBSOURCE.
The pin assignment shown on the encoder end relates to Kollmorgen motors.
132
Kollmorgen | kdn.kollmorgen.com | October 2017