AKD Installation | 9 Electrical Installation
9.13.2 Command encoder signal connection
9.13.2.1 Incremental encoder input 5 V (X9)
A 5 V A quad B encoder, or the encoder emulation output of another drive can be connected
to this input and used as a commander encoder, dual loop feedback, gearing or camming
input. Parameter setting FB2.MODE = 0, FB2.SOURCE=1.
Don't use for primary motor feedback connection!
Connection Diagram
9.13.2.2 Incremental encoder input 24 V (X7)
A 24 V A quad B encoder can be connected to the digital inputs 1 and 2 and used as a com-
mander encoder, dual loop feedback, gearing or camming input.
Parameter setting FB2.MODE = 0, FB2.SOURCE=2.
Don't use for primary motor feedback connection!
Connection Diagram