9.21.7 sercos
®
III
AKD drives (connection variant S3) can be connected as slaves to the sercos
®
III network
via RJ-45 connectors X5 (in port) and X6 (out port). Line and ring topologies are possible. The
communication status is indicated by the built-in connector LEDs.
Available from firmware revision 1.11, the protocol works with Hypertherm masters only.
Connector
LED#
Name
Function
X5
LED1
IN port Link
ON = active,
OFF= not active
LED2
RUN
ON = running,
OFF = not running
X6
LED3
OUT port Link
ON = active,
OFF = not active
LED4
-
-
AKD Installation | 9 Electrical Installation