AKD Installation | 9 Electrical Installation
9.12.8 Encoder with BiSS
9.12.8.1 BiSS (Mode B) analog
The diagram below shows the wiring of a single-turn or multi-turn encoder with BiSS Mode B
interface as a feedback system. The thermal control in the motor is connected via the
encoder cable and evaluated in the drive.
If cable lengths of more than 50 m are planned, please consult customer support.
Type
FBTYPE
Up
Frequency Limit
BiSS (Mode B)
Analog
32
5.1 V +/-5%
1 MHz,
250 kHz for encoders that require ter-
mination resistors
The pin assignment shown on the encoder end relates to Kollmorgen motors.
128
Kollmorgen | kdn.kollmorgen.com | October 2017
Содержание AKD series
Страница 162: ...AKD Installation 9 Electrical Installation Wiring diagram X24 162 Kollmorgen kdn kollmorgen com October 2017 ...
Страница 179: ...9 20 6 CAN Bus Wiring AKD Installation 9 Electrical Installation Kollmorgen kdn kollmorgen com October 2017 179 ...
Страница 214: ... AKD Installation 11 Index 214 Kollmorgen kdn kollmorgen com October 2017 ...