AKD Installation | 7 Technical description and data
7.14.2 Switch-off behavior
The drive’s 24 V supply must remain constant. Hardware Enable input disables the power
stage immediately. Configured Digital Inputs and fieldbus commands can be used to per-
form controlled stops.
7.14.2.1 Switch-off behavior using the DRV.DIS command
The enable/disable button in WorkBench issues a
drv.dis
command internally to the drive.
See
WorkBench Online Help
for configuring inputs and software commands. Sometimes this
enable signal is called "Software Enable" (SW-Enable).
DRV.DISMODE
DRV.DISMODE controls the behavior of the
drv.dis
command issued
through WorkBench, or terminal, or fieldbus. Consult the
WorkBench
Online Help
for configuring.
0
Disable axis immediately, if velocity drops below threshold
CS.VTHRESH
or timeout occurs brake is applied. Category 0 stop
according to IEC 60204 (
2
Use controlled stop to disable drive, if velocity drops below threshold
CS.VTHRESH
or timeout occurs brake is applied. Category 1 stop
according to IEC 60204 (
If velocity drops below threshold
CS.VTHRESH
or timeout occurs brake is applied