AKD Installation | 9 Electrical Installation
9.14.7.2 FAULT relay contacts
Operational readiness (terminals X8/1 and X8/2 ) is signaled by a floating relay contact.
The fault relay can be programmed to two modes of operation:
- Contact closed when there is no fault
- Contact closed when there is no fault and the drive is enabled.
The signal is not influenced by the enable signal, the I²t-limit, or the regen threshold.
FAULT: Relay output, max. 30 VDC or 42 VAC, 1 A
Time to close: max. 10 ms
Time to open: max. 10 ms
All faults cause the FAULT contact to open and the output stage to be switched off (if the
FAULT contact is open, the output stage is inhibited -> no power output). List of the fault
messages: (
Wiring diagram
160
Kollmorgen | kdn.kollmorgen.com | October 2017