AKD Installation | 7 Technical description and data
AKD-x048
Inputs STO-Enable 1/2 (X1)
Outputs STO-Status 1/2 (X1)
Reference ground is STO GND
High Level 24 V ±10%, 16 to 25 mA
Low level 0...5 VDC
Reaction time < 10 ms
Galvanic isolation for 250 VDC
Reference ground is STO GND
As per EN61131-2 type 1
Max. 30 VDC (PELV), max. 100mA
PELV acc. to EN 60204-1
Galvanic isolation for 250 VDC
Pin Description
Pin Description
1
+24 VDC Auxiliary voltage
5
STO-Status 1
2
24V Supply GND
6
STO-Enable 1
3
STO +24 VDC supply voltage
7
STO-Status 2
4
STO GND
8
STO-Enable 2
58
Kollmorgen | kdn.kollmorgen.com | October 2017
Содержание AKD series
Страница 162: ...AKD Installation 9 Electrical Installation Wiring diagram X24 162 Kollmorgen kdn kollmorgen com October 2017 ...
Страница 179: ...9 20 6 CAN Bus Wiring AKD Installation 9 Electrical Installation Kollmorgen kdn kollmorgen com October 2017 179 ...
Страница 214: ... AKD Installation 11 Index 214 Kollmorgen kdn kollmorgen com October 2017 ...