9.12.9 Sine Encoder with EnDat 2.1
The diagram below shows the wiring of a single-turn or multi-turn sine-cosine encoder with
EnDat 2.1 interface as a feedback system. Preferred types are the ECN1313 and EQN1325
encoders. The thermal control in the motor is connected via the encoder cable and evaluated
in the drive. All signals are connected using our pre-assembled encoder connection cable. If
cable lengths of more than 50 m are planned, consult customer support.
Type
FBTYPE
Frequency Limit
ENDAT 2.1
30
1 MHz,
250 kHz for encoders that require termination resistors
The pin assignment shown on the encoder end relates to Kollmorgen motors.